Close Go back Collapse all sections
Process Data set: [CicloData] 2023- electricity production, photovoltaic, 570kWp open ground installation, multi-Si (en) en

Key Data Set Information
Location CL
Reference year 2008
Name
[CicloData] 2023- electricity production, photovoltaic, 570kWp open ground installation, multi-Si
Classification
Class name : Hierarchy level
  • ILCD: #ECOED / #CICLODATA / Electricidad / 2023 / Electricidad SEN 2023 H, M, L voltage / Produccion de electricidad | Combustibles / Fuentes de generacion
General comment on data set ecoQuery: https://ecoquery.ecoinvent.org/3.10/cutoff/dataset/14254/documentation This dataset represents the production of grid-connected low voltage electricity with a 570 kWp open ground photovoltaic (PV) plant the UK in 2012. Large central photovoltaic power stations in the higher kilowatt to megawatt range can feed directly into the medium- or high voltage grid. However, the voltage depends largely on the design and size of the plant. In order to treat all photovoltaic installations the same way (no matter which size, design and installation type (building integrated or open ground)), low voltage electricity is assumed as a product in this dataset. Please see field "extrapolations" for further discussion. ;The plant consists out of multi-Si panel modules with a total capacity of 570 kWp. ;An inverter is used to convert the low voltage DC power into AC power. ;An average yield of {{yield}} was assumed for the calculations. From the PV module installed and ready to be used. This activity ends with low voltage electricity produced with the 570 kWp module, assuming an average yield. This dataset includes tap water use for cleaning the module and its treatment.
Copyright Yes
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2023
Time representativeness description The annual production volume valid for 2012
Technological representativeness
Technology description including background system Electricity production with a grid-connected 570 kWp multi-Si photovoltaic open ground installation. See field "extrapolation" for comment on the output voltage.
LCI method and allocation
Type of data set Unit process, black box
LCI Method Principle Other
Data sources, treatment and representativeness
Data treatment and extrapolations principles The simplifying assumption was made that all electricity is directly provided as low voltage electricity, so that no transformation has to take place. Even in countries with high shares of open ground installations (where medium or high voltage electricity might arrive at the busbar), the error introduced due to this assumption is not significant, as transformation processes do only have a low influence on environmental impacts.
Sampling procedure Literature data/manufacturer data.
Completeness
Completeness of product model No statement
Data generator
Data set generator / modeller
Data entry by
Time stamp (last saved) 2024-07-12T18:43:19.756000-04:00
Data set format(s)
Data entry by
Publication and ownership
UUID c573d564-1965-45ea-ba8a-be10a7f671d8
Date of last revision 2024-07-12T18:41:45.320000-04:00
Data set version 00.00.007
Unchanged re-publication of
Copyright Yes

Inputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow F:Construction / 42:Civil engineering / 422:Construction of utility projects / 4220:Construction of utility projects GLO 3.19E-8 Item(s)3.19E-8 Item(s)
Product flow E:Water supply; sewerage, waste management and remediation activities / 36:Water collection, treatment and supply / 360:Water collection, treatment and supply / 3600:Water collection, treatment and supply CL 0.00295 kg0.00295 kg
Elementary flow Resources / Resources from air / Renewable energy resources from air CL 3.85 MJ3.85 MJ

Outputs

Type of flow Classification Flow Location Mean amount Resulting amount Minimum amount Maximum amount
Product flow D:Electricity, gas, steam and air conditioning supply / 35:Electricity, gas, steam and air conditioning supply / 351:Electric power generation, transmission and distribution / 3510:Electric power generation, transmission and distribution CL 3.6 MJ3.6 MJ
Waste flow E:Water supply; sewerage, waste management and remediation activities / 37:Sewerage / 370:Sewerage / 3700:Sewerage CL 2.66E-6 m32.66E-6 m3
Elementary flow Emissions / Emissions to air / Emissions to air, unspecified CL 2.95E-4 m32.95E-4 m3
Elementary flow Emissions / Emissions to air / Emissions to urban air close to ground 0.25 MJ0.25 MJ