| Key Data Set Information | |
| Location | CL |
| Reference year | 2020 |
| Name |
|
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | ecoQuery: https://ecoquery.ecoinvent.org/3.10/cutoff/dataset/6106/documentation This dataset represents the transformation of electricity voltage from high to medium voltage. The losses are based on electricity generation and trade statistics: IEA World Energy Statistics and Balances, ISSN: 16834240, https://doi.org/10.1787/enestats-data-en Definition of the voltage levels: - High voltage level above 24 kV (large scale industry) - Medium voltage level between 1 kV and 24 kV (medium to small scale industry, service sector and public buildings) - Low voltage level below 1 kV (Households) This activity starts with the high voltage electricity arriving at the transformer station. This activity ends with 1kWh of high voltage electricity transformed to medium voltage. This dataset includes the losses during voltage transformation. It doesn't include the transformer station itself as this is included in the dataset for the transmission network. |
| Copyright | Yes |
| Quantitative reference | |
| Reference flow(s) |
|
| Time representativeness | |
| Data set valid until | 2023 |
| Technological representativeness | |
| Technology description including background system | Transformers are essential components of the electricity grid. They connect the different voltage levels.;Big power plants feed the electricity at a very high voltage to the electricity grid. Transformers between 600 MVA and 80 MVA can be found in substations, where the high transmission voltage is transformed to the medium distribution voltage. In an additional step the medium voltage is transformed to low voltage using transformers below 2.5 MVA. The small transformers below 2.5 MVA are allocated to the low voltage level, whereas all the other transformers are allocated to the medium voltage level. |
| LCI method and allocation | |
| Type of data set | Unit process, black box |
| LCI Method Principle | Other |
| Data sources, treatment and representativeness | |
| Data source(s) used for this data set | |
| Completeness | |
| Completeness of product model | No statement |
| Data generator | |
| Data set generator / modeller | |
| Data entry by | |
| Time stamp (last saved) | 2024-07-12T18:43:19.852000-04:00 |
| Data set format(s) | |
| Data entry by | |
| Publication and ownership | |
| UUID | 65b07149-2844-44f8-9810-7eb9ad55e802 |
| Date of last revision | 2024-06-24T16:49:30.461000-04:00 |
| Data set version | 00.00.005 |
| Unchanged re-publication of | |
| Copyright | Yes |
Inputs
| Type of flow | Classification | Flow | Location | Mean amount | Resulting amount | Minimum amount | Maximum amount | ||
|---|---|---|---|---|---|---|---|---|---|
| Product flow | D:Electricity, gas, steam and air conditioning supply / 35:Electricity, gas, steam and air conditioning supply / 351:Electric power generation, transmission and distribution / 3510:Electric power generation, transmission and distribution | CL | 3.61338499544904 MJ | 3.61338499544904 MJ | |||||
| |||||||||
Outputs
| Type of flow | Classification | Flow | Location | Mean amount | Resulting amount | Minimum amount | Maximum amount |
|---|---|---|---|---|---|---|---|
| Product flow | D:Electricity, gas, steam and air conditioning supply / 35:Electricity, gas, steam and air conditioning supply / 351:Electric power generation, transmission and distribution / 3510:Electric power generation, transmission and distribution | CL | 3.6 MJ | 3.6 MJ |